Moody chart and friction factor

Enter the flow and pipe data to get Re, the Darcy friction factor and the head loss, and see where the point sits on the Moody chart.

Reynolds number1.270e5turbulent
Relative roughness eps/D4.500e-4
Darcy friction factor f0.01951Colebrook
Haaland estimate (check)0.019271.2% off
Major head loss h_f = f (L/D) v^2 / 2g1.604 m
Pressure drop rho g h_f15.73 kPa

Colebrook: 1/sqrt(f) = -2 log10( (eps/D)/3.7 + 2.51/(Re sqrt(f)) ), solved by iteration. g = 9.81 m/s^2. Typical roughness values vary between sources; use the one your question gives.

1031041051061071080.0060.0080.010.0150.020.030.040.050.060.080.1Reynolds number ReDarcy friction factor flaminarf = 64/Re0.050.040.030.020.0150.010.0050.0020.0010.00050.00020.00010.000050.000010.000001f = 0.0195eps/D